Testing item |
Inspection standard or method |
Test indicators |
||
highlights |
semi-light/plain glass |
no- light |
||
impact resistance |
ISO 6272 |
50kg.cm |
40kg.cm |
40kg.cm |
cupping test |
ISO 1520 |
8mm |
7mm |
7mm |
adhesive force(row lattice method) |
ISO 2409 |
0 levl |
||
bending |
ISO 1519 |
2mm |
3mm |
3mm |
pencil hardness |
ASTM D3363 |
1H-2H |
||
salt spray test |
ISO 7253 |
>500 hours |
||
hot and humid test |
ISO 6270 |
>1000 hours |
||
heat resistance |
150℃X24 hours (white) |
excellent light retention, color difference≤0.3-0.4 |
Notes:
1.The above tests used 0.8mm thick cold-rolled steel plates with a coating thickness of 60-80 microns.
2.The performance index of the above coating may change with the change of color and gloss.
Average coverage:
8-11 sq.m./kg; film thickness 70 microns (calculated with 100% powder coating utilization rate)
Packing and transportation:
cartons are lined with polyethylene bags, net weight is 20kg; Non-hazardous materials can be transported in various ways, but only to avoid direct sunlight, moisture and heat, and avoid contact with chemical substances.
Storage requirements:
Clean, dry, ventilated, away from light, room temperature below 30℃, and should be insulated from fire source, away from heat source.The effective storage period is 6 months from the date of production. After the storage period, it can be re-inspected and used again if the results meet the requirements. All containers must be repackaged and returned to their original packaging after use.
Notes:
All powders are irritating to the respiratory system, so avoid inhaling powder and steam from curing. Try to avoid direct contact between skin and powder coating. Wash skin with water and soap when contact is necessary. If eye contact occurs, wash skin immediately with clean water and seek medical attention immediately. Dust layer and powder particle deposition should be avoided on the surface and dead corner. Tiny organic particles will ignite and cause explosion under static electricity. All equipment should be grounded, and construction personnel should wear anti-static shoes to keep the ground to prevent static electricity.